Sign In
St. John Health System
Lab Catalog


Index:

Potassium Level

Order Name POTASSIUM
Test Number: 2004600
Revision Date 05/28/2021
Test Name Methodology LOINC Code
Potassium Level
Ion-Selective Electrode 2823-3 
SPECIMEN REQUIREMENTS
Specimen Specimen Volume (min) Specimen Type Specimen Container Transport Environment
Preferred 1 mL (0.5) Plasma Lithium Heparin PST (Light Green Top) Refrigerated
Alternate 1 1 mL (0.5) Serum Clot Activator SST Refrigerated
Instructions Stability: Ambient 7 days, Refrigerated 7 days, Frozen 1 year
GENERAL INFORMATION
Testing Schedule Daily 
Expected TAT 1-2 days 
Clinical Use Useful in monitoring metabolic processes, hydration, proper body pH and regulation of appropriate heart and muscle functions. 
CPT Code(s) 84132
Service Provided By Labcorp Oklahoma, Inc.
Lab Section Chemistry