Immune Complex Detection by C1q Binding
Order Name
C1Q BINDIN
Test Number: 5500520
Revision Date 12/12/2022
Test Number: 5500520
Revision Date 12/12/2022
Test Name | Methodology | LOINC Code |
---|---|---|
Immune Complex Detection by C1q Binding
|
Semi-Quantitative Enzyme-Linked Immunosorbent Assay | 27831-7 |
SPECIMEN REQUIREMENTS | ||||
---|---|---|---|---|
Specimen | Specimen Volume (min) | Specimen Type | Specimen Container | Transport Environment |
Preferred | 1 mL (0.1) | Serum | Clot Activator SST | Frozen |
Alternate 1 | 1 mL (0.1) | Serum | Clot Activator (Red Top, No-Gel) | Frozen |
Instructions | Specimen Type: Red-top tube or gel-barrier tube Specimen Storage: FREEZE prior to transport. Samples may be stored at 2(degrees)C to 8(degrees)C for seven days prior to testing. Specimen Collection: Separate serum from cells. Transfer specimen to plastic transport tube before freezing. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. Specimen Stability: Ambient: Not Available, Refrigerated : Not Available, Frozen: Not Available |
GENERAL INFORMATION | |
---|---|
Expected TAT | 4 - 8 days |
Notes | Labcorp Test Code: 096933 |
CPT Code(s) | 86332 |
Internal Comments | LOINC 27831-7 ADDED 4/6/15 11/1/17 link and proc - JK |
Service Provided By | |
Lab Section | Reference Lab |