Sign In
St. John Health System
Lab Catalog


Index:

Alcohol Plasma/Serum

Order Name ALCOHOL
Test Number: 4000800
Revision Date 04/26/2021
Test Name Methodology LOINC Code
Alcohol Plasma/Serum
Enzymatic 5643-2 
SPECIMEN REQUIREMENTS
Specimen Specimen Volume (min) Specimen Type Specimen Container Transport Environment
Preferred 1 mL (0.1 mL) Plasma Lithium Heparin PST (Light Green Top) Refrigerated
Alternate 1 1 mL (0.1 mL) Serum Clot Activator SST Refrigerated
Instructions Use betadine or phisohex prep sponge. Do not use alcohol.
MUST be submitted in unopened original tube as exposure to air will affect result.
Stability: Ambient 2 weeks, Refrigerated 6 months, Frozen 6 months
GENERAL INFORMATION
Testing Schedule Daily 
Expected TAT 24hrs 
CPT Code(s) G0480
Internal Comments 2015
4000800 80320 ALCOHOL 80320
4000800 82055 ALCOHOL 80320

12/17/2018: Added alternate container - SN
1/3/2020 RMLOnline/make G0480 the primary CPT and remove 80320. LabWorks- Remove CPT 80320 leaving only existing G0480  - JK
01/13/2020 Updated methodology to Enzymatic
Service Provided By Labcorp Oklahoma, Inc.
Lab Section Chemistry