Sign In
St. John Health System
Lab Catalog


Index:

Volatile Screen

Order Name VOLATILES
Test Number: 4302200
Revision Date 12/01/2023
Test Name Methodology LOINC Code
Acetone Quant
Gas Chromatography/Mass Spectrometry (GC/MS) 2513-0 
Methanol Level
Gas Chromatography/Mass Spectrometry (GC/MS) n/a 
Isopropanol Level
Gas Chromatography/Mass Spectrometry (GC/MS) n/a 
SPECIMEN REQUIREMENTS
Specimen Specimen Volume (min) Specimen Type Specimen Container Transport Environment
Preferred 3.0mL ( 0.5mL) Serum Clot Activator (Red Top, No-Gel) Spin Separate and Freeze
Instructions Clot Activator (Red Top, No-Gel): Allow to clot then spin, separate serum and freeze ASAP.
Specimen Stability: Room temperature: 2 hours, Refrigerated: 28 days, Frozen: 30 months

As of 12/1/2023 the Ethanol will no longer be reported in this panel.
If needed the Ethanol Screen [4301875]  is orderable separately and performed locally, Separate Specimen is required for Ethanol Screen.
GENERAL INFORMATION
Testing Schedule Sun - Sat 
Expected TAT 24 hours 
Notes Performing Reference Lab: OU Medical Center
CPT Code(s) 84600
Internal Comments 7/13/2017 - Added to RML Online - JLS
8/5/19 added Red No Gel to match HNAM - JK
8/7/19 updated specimen processing for RNG- JK
8/30/19 swapping out primary specimens
9/5/19 removed Green Specimen and instructions: Dark Green No-Gel Heparin (Na or Li): Do not uncap the tube prior to testing. - JK
 1/9/2020 - changed stability from Specimen Stability: Room temperature: 72 hours, Refrigerated: 72 hours, Frozen: unacceptable  to
Specimen Stability: Room temperature: 2 hours, Refrigerated: 28 days, Frozen: 30 months
07/06/2021  Removed Hillcrest Medical as reference lab - SN
Service Provided By Labcorp Oklahoma, Inc.
Lab Section Reference Lab